Product Selection
Diaphragm pressure gauges with limit signal transmitter
types 1100.1109 and 1100.1109 A
cable box laterally fig. 1109
|
Construction: fig. 1100.1109
| |||||
|
NG | flange-Ø d | a | B | D | h ± 2 | m | o |
---|---|---|---|---|---|---|---|
100 | 100 | 17 | 99 | 100 | 127 | 31 | 2 |
160 | 17 | 99 | 100 | 127 | 31 | - | |
160 | 100 | 19 | 102 * | 160 | 157 | 31 | 2 |
160 | 19 | 102 * | 160 | 157 | 31 | 2 | |
250 | 100 | 17 | 102 | 250 | 199 | 31 | - |
160 | 17 | 102 | 250 | 199 | 31 | - | |
* With inductive contact types I 11 or I 22 the measure B increases by 17 mm. |
NG | o₂ | r | r₂ | r₃ | weight appr. kgs |
---|---|---|---|---|---|
100 | 21 | 88 | 23 | 32 | 1,85 |
21 | - | 23 | 32 | 2,95 | |
160 | 21 | 118 | 36 | 50 | 2,35 |
21 | 118 | 36 | 50 | 3,45 | |
250 | 21 | - | 36 | 50 | 3,60 |
21 | - | 36 | 50 | 4,70 | |
dimensions in mm |
Dimensions for triple and quadruple contacts and other special constructions on demand. |
MINIMUM PRESSURE RANGES Each pressure measuring device needs a specified deflecting force for operating the discriminating element. Therefore the integration is only possible with the pressure ranges that are given in the table. |
Connection type | Pressure unit in bar / mbar | ||
---|---|---|---|
measuring flange-Ø 100 mm | measuring flange-Ø 160 mm | ||
1 x low-action | 0,6 bar | 60 mbar | |
2 x low-action | 0,6 bar | 100 mbar | |
3 and 4 x low-action | 0,6 bar | 160 mbar | |
1 x magnet | 0,6 bar | 100 mbar | |
2 x magnet | 0,6 bar | 160 mbar | |
3 and 4 x magnet | 2,5 bar | 250 mbar | |
1 x inductive | 1 x electronic | 0,6 bar | 60 mbar |
2 x inductive | 2 x electronic | 0,6 bar | 60 mbar |
3 and 4 x inductive | 3 x electronic | 0,6 bar | 60 mbar |
1 x pneumatic | 0,6 bar | 60 mbar | |
2 x pneumatic | 0,6 bar | 60 mbar |
On pressure measurement devices with 3 or 4 contacts the limit value pointers are not all necessarily adjustable on top of each other. Therefore you should always specify which pointers must be adjustable about each other respectively where your switching points are. In NG 100 pneumatic limit signal transmitter are only available with a single contact. ELECTRICAL CONNECTION Pressure measuring devices according to 1100.1105 with mechanical limit signal transmitter (low-action- and magnetic contacts) are serially devivered with a cable bushing in the housing back panel and 1 m connection cable. Cable boxes are possible with addtional costs. Devices with inductive contacts have a cable box serially. The cable box is mounted at the right side of the housing. There is one exception: on devices with a housing diameter-Ø 250 mm the cable box is mounted on the housing back side generally. With pneumatic contacts PP- or PE-transducer are mounted on the back side. We will gladly send you dimension drawings on demand. For the exact position of the cabel bushing respectively the cable box please take a look at the drawings on page 1 of the data sheet. Alternative mountings are only possible with additional costs after an inquiry. If a second cable connection box or bushing is necessary, e.g. with 3 x low-action contacts with seperated electric circuits, we would be pleased to send you the according dimension drawing on demand. The used cable is maximal a five-core cable, the cabel bushing has 6 pins with one inclusive ground terminal. Limit signal transmitter are installed below the raised dial plate (HZ-version) by default. With NG 250 and on special demand the limit signal transmitter are mounted on the low-lying dial plate (TZ-versions). |
Please quote the medium, concentration, temperature,
measuring range and NG in inquiries and orders.
We reserve the right to alter technical data.
Product search
- Product Selection
- Hose diaphragm valves
- Hose pinch valves
- Diaphragm valves
- Stop and control valves
- Solenoid valves
- Non-return and swing check valves
- Strainer
- Float valves and floats
- Gate valves
- Ball valves and plug valves
- Safety valves
- Pressure reducing valves
- Butterfly valves
- Pressure gauges
- Actuators
- Valve accessories
- Product search